Baseline atmospheric corrosion in the Geothermal Plant Las Pailas, Guanacaste, Costa Rica.

 

Tallennettuna:
Bibliografiset tiedot
Tekijä: Rodríguez Yáñez, Javier E.
Aineistotyyppi: artículo original
Tila:Versión publicada
Julkaisupäivä:2015
Kuvaus:During the construction of the Las Pailas geothermal plant, atmospheric corrosion was evaluated for 5 years. Atmospheric monitoring and gravimetric analysis with low alloy steel (ASTM A36), were done according to ISO 9223 and its associated procedure. There were low values of pollution by chlorides and sulfates, around 5 mg m-2 día-1 and without important levels of acid rain, despite the proximity of an active volcano, which indicates an atmosphere of “rural type”. TDH’s level was 60 %, initial corrosion speed was 40 μm year-1, and this estabilized after 3 years in 20 µm year-1, with protective oxides. The accumulated corrosion estimated by the model meet ISO Corroag of ISO 9226. The Matlab model produced a best adjustment exponential model with a time dependence factor of 0,89. 
Maa:Portal de Revistas UNED
Organisaatio:Universidad Estatal a Distancia
Repositorio:Portal de Revistas UNED
Kieli:Español
OAI Identifier:oai:revistas.investiga.uned.ac.cr:article/1146
Linkit:https://revistas.uned.ac.cr/index.php/cuadernos/article/view/1146
Access Level:acceso abierto
Sanahaku:Atmospheric corrosion
steel ASTM A36
ISO 9223
ISO 9224
ISO 9225 and ISO 9226.
Corrosión atmosférica
acero ASTM A36
ISO 9225 e ISO 9226.