Baseline atmospheric corrosion in the Geothermal Plant Las Pailas, Guanacaste, Costa Rica.
שמור ב:
מחבר: | |
---|---|
פורמט: | artículo original |
סטטוס: | Versión publicada |
Fecha de Publicación: | 2015 |
תיאור: | During the construction of the Las Pailas geothermal plant, atmospheric corrosion was evaluated for 5 years. Atmospheric monitoring and gravimetric analysis with low alloy steel (ASTM A36), were done according to ISO 9223 and its associated procedure. There were low values of pollution by chlorides and sulfates, around 5 mg m-2 día-1 and without important levels of acid rain, despite the proximity of an active volcano, which indicates an atmosphere of “rural type”. TDH’s level was 60 %, initial corrosion speed was 40 μm year-1, and this estabilized after 3 years in 20 µm year-1, with protective oxides. The accumulated corrosion estimated by the model meet ISO Corroag of ISO 9226. The Matlab model produced a best adjustment exponential model with a time dependence factor of 0,89. |
País: | Portal de Revistas UNED |
מוסד: | Universidad Estatal a Distancia |
Repositorio: | Portal de Revistas UNED |
שפה: | Español |
OAI Identifier: | oai:revistas.investiga.uned.ac.cr:article/1146 |
גישה מקוונת: | https://revistas.uned.ac.cr/index.php/cuadernos/article/view/1146 |
Access Level: | acceso abierto |
מילת מפתח: | Atmospheric corrosion steel ASTM A36 ISO 9223 ISO 9224 ISO 9225 and ISO 9226. Corrosión atmosférica acero ASTM A36 ISO 9225 e ISO 9226. |