Mastering analytical challenges for the characterization of pentacyclic triterpene mono- and diesters of Calendula officinalis flowers by non-aqueous C30 HPLC and hyphenation with APCI-QTOF-MS

 

Guardado en:
Detalles Bibliográficos
Autores: Nicolaus, Christoph, Sievers Engler, Adrian, Murillo Masís, Renato, D’Ambrosio, Michele, Lämmerhofer, Michael, Merfort, Irmgard
Formato: artículo original
Fecha de Publicación:2016
Descripción:Pentacyclic triterpene mono- and diesters have been isolated from Calendula officinalis flowers. GC–MS, APCI-Exactive Orbitrap HR-MS and NMR allowed to identify the triterpene skeleton in various samples (different triterpene mixtures from Calendula n-hexane extract). NMR provided evidence that triterpene diesters are present in the samples as well. However, the corresponding quasi-molecular ions could not be detected by APCI-Exactive Orbitrap HR-MS. Instability of triterpene diesters and loss of a fatty acid residue, respectively, in the ion-source made their MS detection challenging. Thus, a set of new APCI-QTOF-MS methods (using the TripleTOF 5600+ mass spectrometer) were developed which made it eventually possible to solve this problem and confirm the diester structures by MS via quasi-molecular ion [M + H]+ detection. Direct infusion APCI-QTOF MS experiments in MS/MS high sensitivity scan mode with low collision energy and multi-channel averaging acquisition (MCA) allowed the detection of quasi-molecular ions of triterpene diesters for the first time and unequivocally confirmed the presence of faradiol 3,16-dimyristate and -dipalmitate, as well as the corresponding mixed diesters faradiol 3-myristate,16-palmitate and faradiol 3-palmitate,16-myristate. Preferential loss of the fatty acid in 16-position made it possible to distinguish the mixed diesters by MS/MS spectra. Their chromatographic separations turned out to be challenging due to their bulkiness and extended molecular dimensions. However, separation could be achieved by an uncommon non-aqueous RPLC mode with an in-house synthesized C30 phase. Finally, two (U)HPLC-APCI-QTOF-MS methods with C18- and C30-based non-aqueous RPLC provided suitable, sensitive assays to monitor the presence of monoesters and diesters of various triterpenes (faradiol, maniladiol, arnidiol, arnitriol A and lupane-3β,16β,20-triol esters) in the n-hexane extract of C. officinalis with high mass resolution and good mass accuracy.
País:Kérwá
Institución:Universidad de Costa Rica
Repositorio:Kérwá
OAI Identifier:oai:https://www.kerwa.ucr.ac.cr:10669/74424
Acceso en línea:https://www.sciencedirect.com/science/article/pii/S0731708515301989?via%3Dihub
https://hdl.handle.net/10669/74424
Access Level:acceso abierto
Palabra clave:Calendula officinalis
Triterpene mono- and novel diesters
(U)HPLC-APCI-QTOF-MS
non-aqueous RPLC
C30 stationary phase