Interference of lupus inhibitors in prothrombin time assays: effect of reagent variability. a case report.
שמור ב:
| מחבר: | |
|---|---|
| פורמט: | artículo original |
| סטטוס: | Versión publicada |
| Fecha de Publicación: | 2017 |
| תיאור: | Abstract: Lupus anticoagulant exerts an inhibitory effect on phospholipid-dependent coagulation tests, especially on TTP but also on PT. Depending on the type of reagents, its concentration, the technique of measurement and the heterogeneity of the antibodies, we can obtain discrepancies in the interpretation of the inhibitor. We present the case of a hemato-oncologic patient who developed a lupus inhibitor with the discrepancies in coagulation times that affected the clinical management of the patient. |
| País: | Portal de Revistas UCR |
| מוסד: | Universidad de Costa Rica |
| Repositorio: | Portal de Revistas UCR |
| שפה: | Español |
| OAI Identifier: | oai:portal.ucr.ac.cr:article/30491 |
| גישה מקוונת: | https://revistas.ucr.ac.cr/index.php/medica/article/view/30491 |
| מילת מפתח: | anticoagulante lúpico inhibidores de coagulación antifosfolípidos tiempo de protrombina lupus anticoagulant antiphospholipids coagulation inhibitors prothrombin time |