Electrochemical evaluation of stainless steel welded tubes

 

Guardado en:
Detalles Bibliográficos
Autores: Rodríguez-Yáñez, Javier, Saborío-Leiva, Ericka, Mora-Montoya, Daniel
Formato: artículo original
Estado:Versión publicada
Fecha de Publicación:2014
Descripción:The recovery of 316L steel capillaries used in neutral geothermal wells orbital welding by weld is evaluated from the point of view of its resistance to corrosion in the conditions of use, through basic electrochemical techniques. In the pre-treatment is more convenient than carrying out a chemical pickling prior to welding for 5 minutes. While subsequent to the application of welding heat treatment of stress reduction is not justified from the standpoint of corrosion resistance. There is also the comparison of capillaries capillary soldiers regarding new and used soldier’s capillaries having an intermediate behavior between the two.
País:RepositorioTEC
Institución:Instituto Tecnológico de Costa Rica
Repositorio:RepositorioTEC
Lenguaje:Español
OAI Identifier:oai:repositoriotec.tec.ac.cr:2238/7733
Acceso en línea:https://revistas.tec.ac.cr/index.php/tec_marcha/article/view/1696
https://hdl.handle.net/2238/7733
Access Level:acceso abierto
Palabra clave:316L Steel; orbital welding; Tafel; geothermal; pickling
Acero inoxidable 316L; soldadura orbital autógena; Tafel; geotermia; decapado