Interference of lupus inhibitors in prothrombin time assays: effect of reagent variability. a case report.

 

Uloženo v:
Podrobná bibliografie
Autor: Quirós Quirós, William
Médium: artículo original
Stav:Versión publicada
Datum vydání:2017
Popis:Abstract: Lupus anticoagulant exerts an inhibitory effect on phospholipid-dependent coagulation tests, especially on TTP but also on PT. Depending on the type of reagents, its concentration, the technique of measurement and the heterogeneity of the antibodies, we can obtain discrepancies in the interpretation of the inhibitor. We present the case of a hemato-oncologic patient who developed a lupus inhibitor with the discrepancies in coagulation times that affected the clinical management of the patient.
Země:Portal de Revistas UCR
Instituce:Universidad de Costa Rica
Repositorio:Portal de Revistas UCR
Jazyk:Español
OAI Identifier:oai:portal.ucr.ac.cr:article/30491
On-line přístup:https://revistas.ucr.ac.cr/index.php/medica/article/view/30491
Klíčové slovo:anticoagulante lúpico
inhibidores de coagulación
antifosfolípidos
tiempo de protrombina
lupus anticoagulant
antiphospholipids
coagulation inhibitors