Validation Method for Determining Levels of SO42-, NO3-, Cl- and C2O42- in Particulate Matter PM-10 in San José

 

Gespeichert in:
Bibliographische Detailangaben
Autoren: Rodríguez, Susana, Herrera, Jorge
Format: artículo original
Status:Versión publicada
Publikationsdatum:2004
Beschreibung:An analytical method for the determination of nitrate, sulfate, chloride and oxalate in particulate matter (PM-10) collected in the area of San José City, was validated. The samples were collected, using two high volume samplers with volumetric flow controller, in glass fiber filters (20,3 x 25,4 cm) with an average flow of 1,13 m3/min during 24 hours in two different locations. The quantification of the anions was made using an Ion Chromatograph with ionic suppressor. The anions present in the particulate matter was chiefly nirate and sulfate, that constitute about 2,5 % of the weigh of the collected particles
Land:Portal de Revistas UNA
Institution:Universidad Nacional de Costa Rica
Repositorio:Portal de Revistas UNA
Sprache:Español
OAI Identifier:oai:ojs.www.una.ac.cr:article/12044
Online Zugang:https://www.revistas.una.ac.cr/index.php/ambientales/article/view/12044
Stichwort:Partículas, PM-10