Validation Method for Determining Levels of SO42-, NO3-, Cl- and C2O42- in Particulate Matter PM-10 in San José

 

Zapisane w:
Opis bibliograficzny
Autorzy: Rodríguez, Susana, Herrera, Jorge
Format: artículo original
Status:Versión publicada
Data wydania:2004
Opis:An analytical method for the determination of nitrate, sulfate, chloride and oxalate in particulate matter (PM-10) collected in the area of San José City, was validated. The samples were collected, using two high volume samplers with volumetric flow controller, in glass fiber filters (20,3 x 25,4 cm) with an average flow of 1,13 m3/min during 24 hours in two different locations. The quantification of the anions was made using an Ion Chromatograph with ionic suppressor. The anions present in the particulate matter was chiefly nirate and sulfate, that constitute about 2,5 % of the weigh of the collected particles
Kraj:Portal de Revistas UNA
Instytucja:Universidad Nacional de Costa Rica
Repositorio:Portal de Revistas UNA
Język:Español
OAI Identifier:oai:ojs.www.una.ac.cr:article/12044
Dostęp online:https://www.revistas.una.ac.cr/index.php/ambientales/article/view/12044
Słowo kluczowe:Partículas, PM-10