Interference of lupus inhibitors in prothrombin time assays: effect of reagent variability. a case report.

 

Wedi'i Gadw mewn:
Manylion Llyfryddiaeth
Awdur: Quirós Quirós, William
Fformat: artículo original
Statws:Versión publicada
Dyddiad Cyhoeddi:2017
Disgrifiad:Abstract: Lupus anticoagulant exerts an inhibitory effect on phospholipid-dependent coagulation tests, especially on TTP but also on PT. Depending on the type of reagents, its concentration, the technique of measurement and the heterogeneity of the antibodies, we can obtain discrepancies in the interpretation of the inhibitor. We present the case of a hemato-oncologic patient who developed a lupus inhibitor with the discrepancies in coagulation times that affected the clinical management of the patient.