Interference of lupus inhibitors in prothrombin time assays: effect of reagent variability. a case report.

 

Kaydedildi:
Detaylı Bibliyografya
Yazar: Quirós Quirós, William
Materyal Türü: artículo original
Durum:Versión publicada
Yayın Tarihi:2017
Diğer Bilgiler:Abstract: Lupus anticoagulant exerts an inhibitory effect on phospholipid-dependent coagulation tests, especially on TTP but also on PT. Depending on the type of reagents, its concentration, the technique of measurement and the heterogeneity of the antibodies, we can obtain discrepancies in the interpretation of the inhibitor. We present the case of a hemato-oncologic patient who developed a lupus inhibitor with the discrepancies in coagulation times that affected the clinical management of the patient.
Ülke:Portal de Revistas UCR
Kurum:Universidad de Costa Rica
Repositorio:Portal de Revistas UCR
Dil:Español
OAI Identifier:oai:archivo.portal.ucr.ac.cr:article/30491
Online Erişim:https://archivo.revistas.ucr.ac.cr/index.php/medica/article/view/30491
Anahtar Kelime:anticoagulante lúpico
inhibidores de coagulación
antifosfolípidos
tiempo de protrombina
lupus anticoagulant
antiphospholipids
coagulation inhibitors
prothrombin time