Two methods for the quantification of paraquat in Soluble Concentrate pesticides

 

Guardado en:
Detalles Bibliográficos
Autores: Pérez López, Esteban, Barrantes Barrantes, Ericka, Villalobos Landazuri, Roberto
Formato: artículo original
Estado:Versión publicada
Fecha de Publicación:2020
Descripción:Introduction: In Costa Rica, paraquat is the third most imported pesticide and it is widely applied in different plantations. This makes it necessary to have a strict quality control for compliance with local regulations Objective: To verify and compare AOAC standard methods 969.09 by UV-Vis spectrometry and the respective CIPAC method by HPLC. Method: The guidelines described by the Costa Rican Accreditation Body (ECA) were followed to verify analytical performance parameters in standardized methods. Results: The UV and HPLC methods proved suitable but had significant differences in the results. Conclusions: Both methodologies comply with the requirements but we recommend an enlarged test with more analysts and laboratories to define which is more accurate.
País:Portal de Revistas UNED
Institución:Universidad Estatal a Distancia
Repositorio:Portal de Revistas UNED
Lenguaje:Español
OAI Identifier:oai:revistas.investiga.uned.ac.cr:article/3042
Acceso en línea:https://revistas.uned.ac.cr/index.php/cuadernos/article/view/3042
Access Level:acceso abierto
Palabra clave:Pesticides
Paraquat
Methodology
Verification
Quality control
Plaguicidas
Metodología
Verificación
Control de calidad