Two methods for the quantification of paraquat in Soluble Concentrate pesticides

 

Αποθηκεύτηκε σε:
Λεπτομέρειες βιβλιογραφικής εγγραφής
Συγγραφείς: Pérez López, Esteban, Barrantes Barrantes, Ericka, Villalobos Landazuri, Roberto
Μορφή: artículo original
Κατάσταση:Versión publicada
Ημερομηνία έκδοσης:2020
Περιγραφή:Introduction: In Costa Rica, paraquat is the third most imported pesticide and it is widely applied in different plantations. This makes it necessary to have a strict quality control for compliance with local regulations Objective: To verify and compare AOAC standard methods 969.09 by UV-Vis spectrometry and the respective CIPAC method by HPLC. Method: The guidelines described by the Costa Rican Accreditation Body (ECA) were followed to verify analytical performance parameters in standardized methods. Results: The UV and HPLC methods proved suitable but had significant differences in the results. Conclusions: Both methodologies comply with the requirements but we recommend an enlarged test with more analysts and laboratories to define which is more accurate.
Χώρα:Portal de Revistas UNED
Ίδρυμα:Universidad Estatal a Distancia
Repositorio:Portal de Revistas UNED
Γλώσσα:Español
OAI Identifier:oai:revistas.investiga.uned.ac.cr:article/3042
Διαθέσιμο Online:https://revistas.uned.ac.cr/index.php/cuadernos/article/view/3042
Λέξη-Κλειδί :Pesticides
Paraquat
Methodology
Verification
Quality control
Plaguicidas
Metodología
Verificación
Control de calidad