Experimental Tests to Determine the Capacity of Prefabricated Concrete Columns

 

Salvato in:
Dettagli Bibliografici
Autori: Villalobos Ramírez, Francisco, Alfaro Martínez, José Pablo
Natura: artículo original
Status:Versión publicada
Data di pubblicazione:2014
Descrizione:This document develops a method for comparison and correlation of two methods for testing reinforced concrete prefabricated columns. The main objective of this article is to simplify the quality control methods in this field and bring information on how to extrapolate the results that may be obtained from a simpler testing method as the ASTM C78M, Standard Test Method for Flexural Strength of Concrete (using simple beam with third-point loading) to a method which represents better the condition of loading that often are used in analytical design of this elements, which is the Method for Flexural Strength of Concrete (using cantilevered beam at 0,220 · L and loaded at 0,728 · L). For the investigation 5 producing factories of columns were evaluated, For each factory, were 7 columns were tested with a method and 7 columns with the other method. The experimental result indicates that apparently does not exist significant difference between both methods.
Stato:Portal de Revistas UCR
Istituzione:Universidad de Costa Rica
Repositorio:Portal de Revistas UCR
Lingua:Español
OAI Identifier:oai:portal.ucr.ac.cr:article/13472
Accesso online:https://revistas.ucr.ac.cr/index.php/materiales/article/view/13472
Keyword:Columnas prefabricadas
tercio medio
carga en voladizo
capacidad en flexión
Prefabricated Columns
Third-Point Loading
Cantilever Loading
Flexural Strength